User Self Diagnosis Ensure comms cable between EBL and control panel is OK () Ensure there is mains power to the IEC lead Remove connectors and inspect for burned pins and/or ones that have opened up If unit will not switch on - ensure you have 0V/Earth on Block 2 pin 2 and 12V on Block 2 pin 5 Ordering Information You need to send both the EBL unit and Control Panel as the root cause is often on a different unit to the part that the fault is showing on. Please continue to the Order Form and complete as much detail as possible in the 'Symptoms' box. Burned out pins on front Don't see your fault? Don't worry - we can still help.Fridge and/or split charger not working whilst driving.No 'mains on' symbol on control panel (Note: this symbols actually indicate charger is switched on NOT mains is connected).Battery goes flat and system switches off. Often fitted to Hymer vehicles Applicable Models EBL 100 (911.500), EBL 100 A (911.501), EBL 100 B (911.502), EBL 100-2 (911.503) Images Front panel EBL 100 front Typical Faults and Symptoms It needs to be paired with a Schaudt control panel - usually one from the DT or IT series. Product Name or Number Schaudt Elektroblock EBL 100 Description This is a charger/power supply and 12V distribution unit used mainly in motorhomes.